Enable-IT 350 Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 17
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
NCV8772
http://onsemi.com
2
Driver
With
Current
Limit
GND
EnableEN
RO
Thermal
Shutdown
Oscillator
Reference
Erorr Amplifier Reset Comparator
Timing
Circuit
Reset Driver
Figure 2. Simplified Block Diagram
V
in
V
out
* D2PAK7 ONLY
** PullDown Resistor (typ 150 kW) active only in Reset State
DT**
***
*
* 5 V OPTION ONLY
*
*
PIN CONNECTIONS
1
Figure 3. Pin Connections
D
2
PAK5
PIN 1. V
in
2. RO
Tab, 3. GND
4. EN
5. V
out
1
DPAK5 D
2
PAK7
PIN 1. V
in
2. RO
Tab, 3. GND
4. EN
5. V
out
PIN 1. V
in
2. RO
3. NC
Tab, 4. GND
5. EN
6. DT
7. V
out
1
PIN FUNCTION DESCRIPTION
Pin No.
DPAK5
D2PAK5
Pin No.
D2PAK7
Pin Name Description
1 1 V
in
Positive Power Supply Input. Connect 0.1 mF capacitor to ground.
2 2 RO
Reset Output. 30 kW internal Pullup resistor connected to V
out
. RO goes Low when V
out
drops by more than 7% (typ) from its nominal value (for NCV8772y devices with y = 1,2,3,...)
or more than 10% (typ) from its nominal value (for NCV8772y devices with y = A, B, C,...).
3 NC Not Connected
3, TAB 4, TAB GND Power Supply Ground.
4 5 EN Enable Input. Low level disables the IC.
6 DT Reset Delay Time Select. Short to GND or connected to V
out
to select time.
5 7 V
out
Regulated Output Voltage. Connect 1 mF capacitor with ESR < 100 W to ground.
Vue de la page 1
1 2 3 4 5 6 7 ... 16 17

Commentaires sur ces manuels