11-6 Specifications
Transducer
Clamp-On
Standard: GE Panametrics’ clamp-on and wetted
transducers
Standard
Temperature Range: -40 to 100° C (-40 to 212° F)
Standard
Frequency: 1 MHz
Note: Transducers for wetted and special applications are
available. Flowcells are also available. Consult the
factory for details.
Optional Materials: Stainless steel, high-temperature plastics,
Hastelloy, Monel, Titanium, etc.
Optional
Temperature Range: -200 to 260° C (-328 to 500° F)
Optional
Frequencies: 500 kHz, 2 MHz, 4 MHz
Mounting: Slide track mounting fixture
Temperature Transducers
Loop-powered 3-wire platinum RTD’s; clamp-on and wetted
(thermowell) types are available.
Accuracy: 0.1° C (0.2° F), wetted RTD’s (matched pairs)
Range: -20 to 260° C (-4 to 500° F)